![]() |
![]() |
|||||||
Midi
(Hive Bee) 10-25-03 21:15 No 466714 |
![]() |
SnCl4 | ||||||
Can someone give a detailed method on transfering this chemical from point A to B, point A being a large container, point B being a smaller 50ml flask w/stopper. I attempted to do this, and it was very hard to tell how much was being poured out of bottle as a shit load of what smelled like hcl gas came out of the mother bottle, making it hard to judge amounts. I suspect about 20ml's made it in there before I had to vacate the area due to the gas this chem released. When I put the capo back on the mother bottle it fumed for a minute or two with the cap on tight!! It was not flushed with nitrogen as none was around at the time. Will this cause problems when I go to reopen the mother bottle? The work space had been purged of moisture with a heavy duty dehumidifier, but that didn't seem to stop the fumes from being released from the liquid. Would this stuff fume in 0% humidity? Most importantly, and my biggest concern is the mother bottle not being purged with N2 before caping it back up for storage. Will the small amount of o2/moisture that may have been in the air and may have made it's way into the mother bottle (95% full) react with the SnCl4 being stored in it? If so, will it just react till the moisture is consumed? Is a fume hood needed to perform small 1-10 ml SnCl4 rxn's safely? I know it's preffered, but is it necessary? Lastly, what are those fumes? It smelled identical to hcl gas, but way more concentrated. I may have inhaled a small amount, but im alive and typing! ![]() First time SnCl4 user, Midi http://www.greenspun.com/bboard/q-and-a- |
||||||||
![]() |
![]() |
|||||||
![]() |
![]() |
|||||||
stratosphere (Hive Bee) 10-25-03 22:13 No 466727 |
![]() |
was the humidty high? | ||||||
was the humidty high? i can't think of what else would cause SnCl4 to give off HCl fumes. maybe try chilling it to 0C next time, that should slow down the decomposition. |
||||||||
![]() |
![]() |
|||||||
![]() |
![]() |
|||||||
Midi (Hive Bee) 10-25-03 22:39 No 466731 |
![]() |
ahh | ||||||
Good idea! The SnCl4 was room temp at the time it was opened. I don'have a means to measure humidity but I suspect I should find a way. ![]() Thanks for the suggestion! http://www.greenspun.com/bboard/q-and-a- |
||||||||
![]() |
![]() |
|||||||
![]() |
![]() |
|||||||
Midi (Hive Bee) 10-26-03 01:44 No 466762 |
![]() |
Very Nice | ||||||
Upon chilling the SnCl4, it was way more easy to work with, and produced no fumes when left uncapped. ![]() Swim is so happy he could ejaculate on command! Thanks Strat. ![]() http://www.greenspun.com/bboard/q-and-a- |
||||||||
![]() |
![]() |
|||||||
![]() |
![]() |
|||||||
Rhodium (Chief Bee) 10-26-03 02:02 No 466766 |
![]() |
tin(IV)chloride smokescreen | ||||||
If so, will it just react till the moisture is consumed? Yes, and you will probably end up with some SnOCl2 or similar as a precipitate in the bottle. Don't worry about that though. When tin(IV)chloride reacts with atmospherical moisture, it decomposes to gaseous hydrogen chloride and solid tin oxide: SnCl4+ 2 H2O -> 4 HCl(g) + SnO2 (both will be visible as white smoke) |
||||||||
![]() |
![]() |
|||||||
![]() |
![]() |
|||||||
stratosphere 10-27-03 21:57 |
![]() |
glad i could be of assistance.
(Rated as: insignificant) |
||||||
![]() |
![]() |
|||||||