SHORTY (Hive Addict)
04-21-04 03:03
No 501904
      Melting point significence     

If one were to test the mp of meth made using pseudo/i2/hypo and found the mp to be 162C then what might he possible have. In other words is it common for the mp to be off by 10 degrees when working in a clandestine lab?

I should also add that the mp test was done ghetto style by using a oven.  I put the meth in a glass dish and covered it with glass lid and setup a thermometer right next to it and slowly increased the temp over about 30 minutes.  At 162C the crystals melted into a small puddle without any visible smoke.  Should the substance vaporize at its melting point or just become a liquid?

It wasn't Me!
 
 
 
 
    ADDkid
(Hive Bee)
04-21-04 03:36
No 501924
      While melting points are helpful, I would not...     

While melting points are helpful, I would not get down if the melting point is too off, because just a small percent of impurities can manipulate it drastically.  Melting are good tools, but I am starting to believe that the best tools, are tools like Jones reagent, Tollens test, Lucus test and so on, in the combination of other neat and efficient methods describe in Vogels 5th Ed.  Also, sitting down and figuring out all the side products, (except for bullshit denaturants found it p-fed) and using that information to correctly separate, based on the properties, this method is also found in Vogels 5th Ed.  One more thing, the polarimetry tools is cheap I think, and might be also very helpful.  One could probably just make one.

P.S.  Swig suggest that you find the kind of test that you will need in order to identify any compound that you are likely to run into or synthesize, and before doing anymore reactions make little bottles labeled with there names, (one might use iodine tinc. Bottles) however, Jones reagent seems to eat the top off. Then buy little droplets tubes and then you can run many tests very fast and mess is limited.  Here is a site for most common test, although many more can be found.  These tests are very fun because of the visual and smell changes.  Tollens test produces a mirror with aldehydes.  When swig made benzyl bromide with benzyl alcohol and HBr, Jones test was used to see if the reaction was completed, then swig notice the smell of benzaldehyde very strong, which lets me know that primary alcohol was still present, and the most important, Benzaldehyde has the possibility of being produced and isolated in great yields using the Jones reagent.
http://www.chemistry.ccsu.edu/glagovich/teaching/472/qualanal/tests/tests.html

P.P.S.  When doing the Melting point test in the lab, it seems to turn in to a liquid first and then vaporizes (depends on the compound),  It happens very fast, before it happends it has very faint melting appearants, and then once the point is acheived it has a crumble like visual affect right before it melts, but that is only when using mel-temp.
 
 
 
 
    CharlieBigpotato
04-21-04 04:53
      ignore all potentially unhappy news
(Rated as: off-topic)
    
 
 
 
    ADDkid
04-21-04 04:56
      What? I am confused please explain.
(Rated as: off-topic)
    
 
 
 
    CharlieBigpotato
04-21-04 05:21
      yes, you are confused
(Rated as: insignificant)
    
 
 
 
    ADDkid
04-21-04 06:28
      Every heard of that expression "If you...
(Rated as: redundant)
    
 
 
 
    WizardX
(Wizard Master)
04-21-04 07:18
No 501973
      Tech Grade Solvents     

Tech Grade Solvents can also affect the substrate melting point, because the solvents have impurities. Use a LR grade solvent (or even better AR) with recrystallisation to improve the purity.
 
 
 
 
    kris_1108
04-21-04 09:51
      Karma
(Rated as: insignificant)
    
 
 
 
    Osmium
(Stoni's sexual toy)
04-21-04 11:57
No 502021
      > I should also add that the mp test was...     

> I should also add that the mp test was done ghetto style by using
> a oven.  I put the meth in a glass dish and covered it with glass
> lid and setup a thermometer right next to it and slowly increased
> the temp over about 30 minutes.

This is extremely unreliable. Use an oil bath, a small glass test tube (the smaller the better) and a thermometer. Professional MP apparati use thin glass capillaries (about 1mm diameter) and a magnifying glass to observe the sample, and they only require a few milligrams of material for a MP determination.

BUSH/CHENEY 2004! After all, it ain't my country!
 
 
 
 
    Newton
(Hive Bee)
04-21-04 14:36
No 502037
      Plus, check that thermometer!     

Plus, check that thermometer! By sticking it into boiling water and see if the temperature shown is 100°C +- 1°C.

SWIM had exactly that experience with his first ever meth run. Thermometer showed 160°C at melting point frown, but it later turned out that the actual temperature was 172°C !smile This was confirmed with several (mercury) thermometers. The original one probably contained alcohol. What kind is the one you used?
 
 
 
 
    SHORTY
(Hive Addict)
04-22-04 03:34
No 502170
      Thermometer is fine     

The thermometer test has been done in boiling water and it is working fine.  It is the mercury type 0-200C.  However, my oven theromostat is about 30 degrees off.  No wonder it takes longer than it should to bake cookies!
I know that the proper way is in a oil bath but i don't understand why the way i did it would be so unreliable.  The temp was brought up at a very slow rate and the bulb of the thermometer was fitted right next to the sample being tested.  Also, i use only lab grade solvents. 

Next time i will put a little pseudo in at the same time to see if it is off as well.

It wasn't Me!
 
 
 
 
    Newton
(Hive Bee)
04-22-04 16:11
No 502246
      I know that the proper way is in a oil bath...     

I know that the proper way is in a oil bath but i don't understand why the way i did it would be so unreliable.

The breaking of the crytal lattice (melting, that is) requires energy. So heat is taken up, causing the melting sample to be colder than the environment. This effect will be smaller when oil is used (separated by a thin glass tube wall), as oil has a much larger thermal coefficient than air.
 
 
 
 
    SHORTY
(Hive Addict)
04-22-04 17:20
No 502260
      So would that mean     

That the melting point would have been even lower if i had done the test in oil?

Also, by increasing the heat at a slow rate (1-2 degrees a minute) wouldn't this give a more accurate calculation?

Does the substance being tested have to actually vaporize or just become liquid when testing for the mp?

It wasn't Me!
 
 
 
 
    MarleyBob
(Hive Bee)
04-22-04 17:20
No 502261
      poor apparatus     


The temp was brought up at a very slow rate and the bulb of the thermometer was fitted right next to the sample being tested.




Even in the school lab when I use the real mp testers, its not uncommon for the reading to be 5 or so degrees below what it really is. To get a completely accurate mp test a lot of patience is required, the temp has to be risen very slowly

The fact your reading is 10 degrees below sounds just about right to me for a clandestine setting.


Even if God really existed, it would be necasarry to abolish him
 
 
 
 
    MarleyBob
(Hive Bee)
04-22-04 17:33
No 502264
      liquid     

shorty: mp test requires the solid be turned to a liquid

liquid to vapor is bp test wink

Slowness is key!

Even if God really existed, it would be necasarry to abolish him
 
 
 
 
    SHORTY
(Hive Addict)
04-22-04 17:37
No 502266
      Thats what i thought....     

So what is the bp of meth?

It wasn't Me!
 
 
 
 
    Newton
(Hive Bee)
04-22-04 20:11
No 502299
      That the melting point would have been even...     

That the melting point would have been even lower if i had done the test in oil?

Yeah, you're right. SWIM's original argument should be applied to the bulb of the thermometer, which probably has a larger thermal coefficient than the meth.HCl, and gets warmed too slowly by the air, while the sample has already melted.

All these considerations are under the assumption that the actual mp of your sample _is_ higher than 160°C. It maybe that it is impure, although this is not likely considering the cleaning step Shorty usually performs (this stuff was A/B-ed, steam distilled and recrystallised, right?).

So what is the bp of meth?

SWIM was wondering about this as well not long ago, Rhodium was kind enough to point out that meth-HCL does not have a bp. It starts to decompose before actually boiling.
 
 
 
 
    SHORTY
(Hive Addict)
04-23-04 03:44
No 502374
      At what temp?     

What is the temp at which it has to be heated in order to smoke it?  Or what is the heat at which it decomposes?  Does it have to decompose in order to smoke it?

It wasn't Me!
 
 
 
 
    Rhodium
(Chief Bee)
04-23-04 14:27
No 502451
      both     

When you smoke meth, part of it will decompose (to more or less healthy degradation products, see the FAQ), and part of it will sublime/vaporize (forming an aerosol of intact meth.HCl). The higher the temperature and the longer the heating, the more degradation will occur.

The Hive - Clandestine Chemists Without Borders
 
 
 
 
    Phlegm
(Newbee)
04-24-04 05:57
No 502603
      I find this melting point stuff interesting.     

I find this melting point stuff interesting. I have two apparati that measure melting points purchased as surplus for about $50 each. Fisher-Johns and Elctrothermal brands. They're both old, but were lab standards for years. In fact, I think the Fisher-Johns is still marketed virtually unchanged from the past. Anyway, I bought some commonly available compounds as calibration standards. Both instruments gave almost identical results to Merck's published melting points. So, my confidence in them is high.

Merck lists MA as having a melting point of 170-175 C., which is somewhat broad compared to most compounds. I  tested my last three batches and they came in at 172-174, 170-173, and 174-176. Now, of course, I believe that my shit is some of the best around. But I do not belive that is 100% pure. What I need to research is how much contamination can a compound typically contain and still spec out very close to it's true melting point/range.

As far as rigging a homemade apparatus, I spent a fair amount of time thinking about one and actually started making it, but abandoned it. I just don't think it's worth the time investment. With some searching you can find one reasonably priced.
 
 
 
 
    Rhodium
(Chief Bee)
04-24-04 16:17
No 502672
      Melting point depression calculation
(Rated as: good read)
    

The melting point depression gotten from a certain amount of contamination can only be calculated exactly if the identity of the contaminant(s) is known, as its molecular weight is of importance to the calculation. The melting point depression is proportional to the number of contaminant molecules present: http://members.aol.com/profchm/fpdepres.html

The Hive - Clandestine Chemists Without Borders
 
 
 
 
    auntyjack
(Hive Bee)
05-01-04 19:34
No 504208
      thermometer technique     

does it matter how much of your thermometer is heated?...should you only heat the bulb?

the horror
 
 
 
 
    Rhodium
(Chief Bee)
05-01-04 20:07
No 504210
      Partial/Total Immersion Lab Thermometers     

Some helpful information on ASTM and other glass laboratory thermometers
(taken from http://www.icllabs.com/thergenlinfo.html)

All ASTM and other glass laboratory thermometers can be classified into 2 general groups - those designed and fabricated for total immersion and those designed and fabricated for partial immersion.   If you use glass thermometers, it is essential that you understand the difference, and how each type of thermometer is used!

Most laboratory errors in temperature measurement result from incorrect usage (immersion) of the thermometer!

Total immersion thermometers are designed with scales which indicate actual temperature when the bulb and the entire liquid column are exposed to the temperature being measured. In practice, a short length of liquid column (usually one inch or less) is permitted to extend above the surface of the liquid being measured to permit reading of the thermometer.

Most total immersion thermometers can also be used in a condition of complete immersion, wherein the entire thermometer is exposed to the temperature being measured, as with a thermometer inside a freezer.

Partial immersion thermometers are designed to indicate the actual temperature when a specified portion of its stem is exposed to the temperature being measured.

How can I know the difference?

Partial immersion thermometers will have 1) an inscription on the reverse of the thermometer stating the required immersion depth - ie 76MM IMM or similar marking, and 2) in most cases, a "ring" is inscribed on the stem of the thermometer indicating the depth to which the stem should be submerged.

http://www.icllabs.com/pics/sepblank.JPG

On this line drawing, there is a "ring" inscribed on the thermometer just above the contraction chamber.  If one views the reverse of the thermometer, the inscription 125MM IMM (or as appropriate) should appear.   Accordingly, partial immersion thermometers are easy to identify.

Total immersion thermometers are sometimes a little trickier to identify.  Some of the better manufacturers are inscribing TOTAL or TOTAL IMMERSION on the reverse of the thermometer, but regrettably this is not an industry-wide practice. The photo below is of an ASTM 112C thermometer, which is designed for total immersion.   There is no "ring" inscribed, of course, and there is no "TOTAL IMMERSION" marking on the reverse.

If there is no inscription on the reverse indicating immersion, you should assume the thermometer is designed for total immersion.

http://www.icllabs.com/pics/112c.gif

What's the difference in use?

As explained above, the partial immersion thermometer is immersed in the liquid being measured up to the line, or ring. The total immersion thermometer must be immersed to within approximately one inch of where the mercury column resides at the temperature being measured.

So what happens if the total immersion thermometer is not immersed to the depth it should be?

You will have an erroneous temperature reading.   The amount of the error depends upon what the temperature is that you are measuring, and how much of the thermometer stem that should be immersed is outside the liquid you are measuring.  An extreme example: you have a -1/201C thermometer, 24 inches in length, total immersion, and you are testing the liquid in a beaker on a hotplate.  Only about 2 inches of the thermometer is in the liquid.   The thermometer indicates 190C.  How much error do we have?  Almost 5 degrees C.  The liquid in the beaker is this amount hotter than the thermometer indicates.

I have this expensive, calibrated, total immersion thermometer I bought recently, similar to the one in the example above.  I need it for applications similar to that described.  Is this useless to me?

No, it may not be the best thermometer for your application, but you can use it.  However, you'll need to calculate an 'emergent stem correction', which we will explain below.

The Hive - Clandestine Chemists Without Borders