ADDkid (Hive Bee)
12-18-03 18:53
No 477647
      Getto Drying Tube     

Can one put a sep. funnel(filled with drying agent) that has ground glass, on top of the condenser for dry reflux.
 
 
 
 
    Rhodium
(Chief Bee)
12-18-03 23:42
No 477698
      really ghetto     

It is not a good solution, as the sep funnel valve is so narrow, it could spell disaster if you for any reason would get overpressure inside the reaction setup (the sepfunnel would fall off).

If you decide to use this setup anyway, make sure that you put some kind of filter (i. e. steel wool) at the bottom of the sepfunnel to prevent the drying agent to fall into the rxn mixture.

The Hive - Clandestine Chemists Without Borders
 
 
 
 
    Mercury
(Newbee)
12-20-03 23:20
No 478061
      Perhaps an addition funnel would be more ...     

Perhaps an addition funnel would be more suitable, and less ghetto :-). Addition funnels tend not to have a skinny stem that is typical in sep funnels.
 
 
 
 
    ADDkid
(Hive Bee)
12-26-03 07:01
No 479076
      I can't find a drying tube anywhere, any ...     

I can't find a drying tube anywhere, any suggestions?
 
 
 
 
    sYnThOmAtIc
(Hive Addict)
12-27-03 11:37
No 479272
      Vacuum adaptor     

Take a regular bent vacuum adaptor for the reciever end of a still, stuff a lil cotton in the drip tube(from the condenser opening, don't stuff it just lay over top of hole to stop dessicant) and pour in some dessicant. Plug with cotton or glass wool. Ghetto drying tube with ground joint, viola.

Edit: Oh yea, you'll need to stick a piece of something in the vacuum takeoff nipple. I just ball up some teflon tape like a little joint. The thick center will stop it going all the way in and make a tight seal.
 
 
 
 
    Rhodium
(Chief Bee)
12-27-03 21:56
No 479355
      Inline Gas Dryer: cheap, easy, and OTC     

../rhodium /equipment/inline.gas.dryer.html

The Hive - Clandestine Chemists Without Borders